ProfessorWei Chen

Head of School

Faculty of Engineering

RESEARCH OUTPUTS

  • JOURNAL ARTICLE
    Enhanced Semi-Supervised Detection of Obstructive Sleep Apnea from Single-Lead ECG Using CNN and Transformer Models
    4 Nov 2026IEEE Transactions on Instrumentation and MeasurementPP(99):1Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Wang K,
    • Li Y,
    • Hu X
    DOIDOI: 10.1109/tim.2026.3746797 (opens in a new tab)⁠
    Obstructive Sleep Apnea (OSA) is a common sleep disorder that poses significant health risks. Given the close relationship between cardiac and respiratory functions, respiratory changes caused by OSA can be effectively captured through electrocardiogram (ECG) signals. This study proposes an OSA detection algorithm based on single-lead ECG signals combined with simplified denoising processing. Specifically, to address the high demand for manually labeled data in deep learning, we propose an enhanced and easy-to-implement semi-supervised learning method (ESSL) to explore accurate OSA detection with a small amount of manually labeled data. A hybrid architecture (CRFNet) integrating Convolutional Neural Network (CNN), ResNet, and multi-scale Transformer modules is also proposed. On the PhysioNet Apnea-ECG dataset, the semi-supervised learning method combined with CRFNet achieved an accuracy of 89.82±0.39%, specificity of 88.94±1.04%, and sensitivity of 90.74±0.84% using 20% labeled data, which is close to the fully supervised learning results with 100% labeled data. On the Huashan Hospital dataset (HHD), the same model using the semi-supervised learning method also approaches the results of fully supervised learning. In the intra-dataset evaluation on another public dataset (UCDDB), the proposed ESSL similarly achieves near-fully supervised performance, while in the cross-dataset evaluation, the ESSL method improves the cross-dataset generalization of automatic OSA detection. Comparative results demonstrate competitive classification performance, while the intra- and cross-dataset evaluations further support the robustness and generalization capability of the proposed framework. By relying on easily accessible single-lead ECG signals and a semi-supervised learning approach that reduces the need for extensive labeling, this method provides a cost-effective and accurate solution for automated OSA detection.
  • JOURNAL ARTICLE
    APTGNet: The age-prompted and text-guided EEG model for epilepsy detection across all-age groups
    Nov 2026Biomedical Signal Processing and Control127:111072Elsevier
    Co-authors:
    • Liu M,
    • Xie X,
    • Xu L
    DOIDOI: 10.1016/j.bspc.2026.111072 (opens in a new tab)⁠
    Epilepsy is a neurological disorder characterized by abnormal discharges in the brain, which can occur at any age. Seizures not only have the potential to cause cognitive impairments but also lead to anxiety, depression, and social isolation, severely impacting the quality of life for patients. Therefore, research on epilepsy detection across all-age groups is of significant importance. Electroencephalography (EEG) is a commonly used tool for diagnosing epilepsy, as analyzing EEG signals can help determine seizure events. Existing epilepsy detection models typically rely on EEG data from a single age group, limiting their generalization capabilities and applicability. This study proposes a text-guided model for epilepsy detection in patients across all ages, involving four publicly available datasets that encompass neonates, children, and adults. The APTGNet model uses age prompts combined with textual contrastive learning to train the model, achieving epilepsy classification across all-age groups. The model consists of a text encoder and an EEG encoder, where the text encoder converts text into high-dimensional semantic features, and the EEG encoder utilizes a Dynamic Attention Module (DAM) to dynamically focus on EEG signals from patients of different age groups. By calculating the cosine similarity between text and EEG features, APTGNet can accurately classify seizure signals, demonstrating strong generalization capabilities and clinical application potential. Our model exhibits good performance across multiple datasets for all-age groups, particularly in the following aspects: (1) strong overall performance in seizure detection datasets across various age groups; (2) effective performance and generalization enabled by text guidance and age prompts; and (3) unifying seizure detection tasks across multiple age groups through the DAM.
  • JOURNAL ARTICLE
    HSleepNet: A hybrid adaptive brain network architecture for neonatal sleep staging
    Nov 2026Biomedical Signal Processing and Control127:111027Elsevier
    Co-authors:
    • Zhou L,
    • Xu Y,
    • Wang L
    DOIDOI: 10.1016/j.bspc.2026.111027 (opens in a new tab)⁠
    Background and objective: Sleep analysis provides an important window into neonatal neurodevelopment, but automatic neonatal sleep staging remains challenging because neonatal EEG is nonstationary, low in signal-to-noise ratio, and strongly affected by inter-channel spatial interactions. Existing approaches often rely on either handcrafted connectivity features or purely data-driven deep learning features, and therefore may not fully exploit complementary functional-connectivity and adaptive spatial information. This study proposes HSleepNet, a hybrid adaptive brain network architecture for neonatal sleep staging. Methods: HSleepNet integrates three key components: (i) a multi-dimensional brain network (MDBN) branch that extracts Pearson correlation, mutual information, phase-locking value, phase-lag index, and phase-slope-index connectivity; (ii) an adaptive brain network (ABN) branch that learns row-normalized channel relationships from CNN–BiLSTM features; and (iii) a spatial feature learning module that fuses connectivity priors and adaptive graph representations. The model was evaluated using subject-wise 10-fold cross-validation on the private CHFD neonatal EEG dataset comprising 64 recordings. MASS-S3 was additionally used as an adult cross-population benchmark rather than as evidence of external neonatal validation. Results: On CHFD, HSleepNet achieved an accuracy of 81.4% and an MF1 score of 0.813 for the three-stage wakefulness–AS–QS task. On MASS-S3, the model achieved an accuracy of 85.6% and an MF1 score of 0.791 for the five-stage adult sleep task. These results suggest that the hybrid MDBN–ABN design provides complementary information for multi-channel EEG sleep staging. Conclusions: HSleepNet provides preliminary evidence that combining domain-informed connectivity features with adaptive graph learning can improve neonatal sleep staging on the studied cohort. The main limitation is that neonatal validation was performed on a single private clinical dataset; therefore, broader external neonatal validation and more extensive clinical outcome analysis are required before making claims about deployment or general clinical utility.
  • JOURNAL ARTICLE
    An Ultra-Low-Power Flexible Wearable EEG–fNIRS System for Prefrontal Monitoring
    29 Oct 2026IEEE Sensors JournalPP(99):1Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Wang S,
    • Yao C,
    • Yap LW
    DOIDOI: 10.1109/jsen.2026.3746364 (opens in a new tab)⁠
    Wearable monitoring of prefrontal cognitive workload requires hybrid systems that overcome critical bottle-necks in power, wearability, andmultimodal integration. This paper presents a fully integrated wireless electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) system for prefrontal sensing. The hardware combines a flexible sensor board with a rigid main board. VCSEL-based fNIRS optodes and soft, dry gold-film coated sponge electrodes are co-located on the flexible interface. During dual-modality acquisition, the average power consumption is 15.49 mW. The system weighs 9.86 g excluding the battery and has a core hardware cost of 61 USD. Under active optical switching, the EEG front end maintains a baseline noise of 0.86 μVRMS. Validation in 20 human participants showed reliable acquisition of physiological EEG and fNIRS signals. During an N-back working-memory task, the system captured load-dependent changes in frontal theta-band power and oxyhemoglobin concentration. Compared to the gold-standard polysomnography (PSG) system, this system achieved a correlation of r = 0.93. For workload estimation, we used an offline decoding pipeline with causal, leakage-free feature construction and fixed late fusion. Under Leave-One-Subject-Out (LOSO) cross-validation, the EEG-only and fNIRS-only models reached mean accuracies of 75.7% and 82.6%, respectively. The fused EEG+fNIRS model reached 90.2% for distinguishing Rest, Low, and High workload states. These findings support the proposed ultra-low-power architecture for multimodal prefrontal workload monitoring.
  • JOURNAL ARTICLE
    Cross-Subject Localization of Epileptogenic Zone for Drug-Resistant Epilepsy Based on the Causal Brain Network
    8 Oct 2026IEEE Transactions on Biomedical EngineeringPP(99):1-12Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Wang Y,
    • Kong W,
    • Liu Y
    DOIDOI: 10.1109/tbme.2026.3741120 (opens in a new tab)⁠
    OBJECTIVE: While neurosurgical treatment is the primary intervention for Drug-resistant epilepsy (DRE) patients, its success rate is limited to approximately 60%. Precise localization of epileptogenic zone (EZ) is a critical factor for surgical success. This study aims to achieve cross-subject localization of the EZ in DRE patients using causal brain network features extracted from stereotactic electroencephalography (SEEG). METHODS: We collected SEEG recordings from 12 DRE patients who achieved complete seizure freedom (Engel Class I). The causal coupling algorithm, full convergent cross mapping (FCCM), was applied to both ictal and interictal states to extract causal brain network features from SEEG recordings. We fed these features into multiple machine learning models to achieve automated identification of EZ within a leave-one-patient-out cross-validation framework. Under a unified evaluation protocol, FCCM was compared with directed information, frequency-domain convergent cross mapping (FD CCM),high-frequencyoscillation-based methods, source-sink con nectivity, and SEEGformer. RESULTS: At the individual level, the Mann-Whitney U test demonstrated that the raw FCCM values sig nificantly differentiated the EZ from the non-epileptogenic zones (NEZ) in 83.3% (10/12) of patients during the ictal state and in all patients (12/12) during the interictal state (p < 0.001). Per mutational multivariate analysis of variance on the 8 dimensional statistical features revealed significant global network variations in 83.3% (10/12) of ictal and 91.7% (11/12) of interictal states (p < 0.001). The combined model, which integrated both ictal and interictal features using the logistic regression classifier, achieved the best performance among all evaluated methods This approach achieved the highest accuracy (0.83 ± 0.10), recall (0.87 ± 0.09), and F1-score (0.80 ± 0.12), while the second-best baseline (FD CCM) yielded an accuracy of 0.79 ± 0.15, a recall of 0.81 ± 0.20, and an F1-score of 0.75±0.18. These results demonstrate that our method achieves state-of-the-art performance. CONCLUSION: Causal brain network features extracted by FCCM are robust biomarkers for localizing the EZ. SIGNIFICANCE: This study could support the development of more personalized treatment strategies for DRE patients. It is expected to promote the development of precision medicine for DRE.
  • JOURNAL ARTICLE
    A 1D Snoring Waveform and 2D Composite Acoustic Feature Graph-Based Multi-Modal Fusion Network for Obstructive Sites Recognition
    Oct 2026IEEE Journal of Biomedical and Health Informatics30(10):8392-8403Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Hu X,
    • Fang R,
    • Luo H
    DOIDOI: 10.1109/jbhi.2026.3670208 (opens in a new tab)⁠
    As a critical factor in diagnostic work-up and treatment decision-making process of sleep-related breathing disorders, accurate localization of obstructive sites in the upper airway is in dire need. Snoring, as a dynamic acoustic signal, carries informative information relating to the sites and degree of obstruction in the upper airway, offering a non-invasive, cost-effective solution for obstructive sites recognition. However, most of existing snoring-based methods for recognizing obstructive sites only involve limited information (either mainly concentrated on traditional acoustic characteristics or spectrogram features), which may omit dynamic pathological information. Moreover, existing methods proceed from either a one-dimensional (1D) signal or two-dimensional (2D) image perspective, where complementary information from the other modality may be overlooked. In this paper, a multi-modal framework, which combines 1D snoring waveform and 2D Composite Acoustic Feature Graph (CAF-Graph), is proposed. 1D snoring waveform perceives fine time structure and local patterns, aiming at learning high-level discriminative representations by neural networks. 2D CAF-Graph is dedicated to emphasizing dynamic spatio-temporal and physiological-acoustic characteristic of snoring, which concatenates acoustic features related to Prosodic, Formant, Spectral, and Cepstral characteristics. Further, a multi-modal fusion network (BMFNet) effectively integrates independent and interactive information between single-modal features, which offers a more comprehensive perspective. The recognition task was formulated as a three-class classification problem, including upper (snoring caused by upper-level obstruction), lower (snoring caused by lower-level obstruction), and silence (obstruction without snoring). The proposed method was validated on a clinical dataset collected in the ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, where it achieved 81.2% Accuracy, 86.8% Weighted Average Precision, 81.2% Weighted Average Recall, and 82.3% Weighted Average F1-Score. Results exhibit the effectiveness of multi-modal feature representations for snoring, providing a novel insight for obstructive sites recognition tasks.
  • JOURNAL ARTICLE
    Data‐Driven Design of Self‐Adhesive Epidermal Electrodes and Sensors
    Oct 2026Advanced Science13(60):e76928Wiley
    Co-authors:
    • Li X,
    • Wang S,
    • Razbin M
    DOIDOI: 10.1002/advs.76928 (opens in a new tab)⁠
    Stretchable and self-adhesive epidermal electrodes and sensors with long-term stability are highly desirable for wearable applications. These electrodes and sensors typically comprise multiple components, each contributing distinct mechanical and electrical functions. However, their materials design and optimization rely heavily on time-consuming trial-and-error approaches, highlighting the need for a more effective strategy. Here, we report a data-driven composition optimization strategy integrating artificial neural network (ANN) modeling and genetic algorithm (GA) optimization for the rational design of self-adhesive epidermal electrodes/sensors. By defining optimization objectives that prioritized either high electrical conductivity and adhesion or high piezoresistive sensitivity, stretchable epidermal electrodes and sensors were developed. The optimized electrode exhibits high stretchability (∼ 177%), robust adhesion (0.10 N cm<sup>-</sup> <sup>1</sup>), and low skin electrode contact impedance (∼ 72 kΩ at 10 Hz), enabling more stable long-term acquisition of electromyograms (EMG), electrocardiograms (ECG), and electroencephalograms (EEG) signals, compared to commercial Ag/AgCl gel electrodes. The resulting optimal sensor based on a different material composition demonstrates large stretchability (∼ 153%) and good piezoresistive sensitivity (gauge factor ∼ 4.79), enabling motion monitoring and human-machine interface demonstrations. This work highlights the effectiveness of data-driven optimization for application-specific design of wearable devices.
  • JOURNAL ARTICLE
    Clinical and Upper Airway Microbial Signatures in Severe Obstructive Sleep Apnea: Association and Prediction
    22 Sep 2026Phenomics1-4Springer Nature
    Co-authors:
    • Liu M,
    • Jin X,
    • Fang R
    DOIDOI: 10.1007/s43657-026-00344-y (opens in a new tab)⁠
  • JOURNAL ARTICLE
    Patient-Specific Non-Invasive Epileptogenic Zone Localization via High-Resolution Time-Frequency Representations and CNN Deep Learning
    17 Aug 2026IEEE Transactions on Biomedical EngineeringPP(99):1-12Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Wang Y,
    • Yuan W,
    • Liu Y
    DOIDOI: 10.1109/tbme.2026.3724147 (opens in a new tab)⁠
    Stereoelectroencephalography (SEEG)-guided radiofrequency thermocoagulation is the mainstream treatment for drug-resistant epilepsy (DRE), yet non-invasive patient-specific localization of potential epileptogenic zone (EZ) prior to SEEG electrode implantation remains a critical unmet clinical need, hindered by limited automation, suboptimal accuracy, and poor cross-patient generalizability. To address these gaps, we developed an automated non-invasive EZ localization framework that integrates scalp EEG source imaging, high-resolution time-frequency analysis, and deep learning. This multicenter retrospective study included 97 seizure episodes from 37 surgically confirmed DRE patients with Engel Class I post-operative seizure freedom. Three time-frequency spectrograms were generated based on the source-reconstructed signal, and fed into four deep learning architectures (ResNet, VGG, DenseNet, Swin Transformer) for channel-level EZ binary classification with patient-level leave one-out cross-validation to validate personalized localization for unseen patients. The ResNet18-Superlet combination achieved optimal performance (accuracy = 81.15% ± 4.83%, AUC = 84.82% ± 5.27%) in the adult cohort, with robust generalization to pediatric and mixed cohorts, significantly outperforming conventional high-frequency oscillation (HFO)-based methods. This framework enables accurate personalized pre-surgical EZ map ping to optimize SEEG implantation planning, with open-source code available at https://github.com/wyl1994/Source-code-for Patient-Specific-Non-Invasive-Epileptogenic-Zone-Localization to ensure reproducibility and clinical translation.
  • PREPRINT
    Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction
    14 Aug 2026arXiv
    Co-authors:
    • Mehdi H,
    • Klen R,
    • Bulbul AK
    DOIDOI: 10.48550/arxiv.2609.22105 (opens in a new tab)⁠
  • CONFERENCE
    Self-Enhanced Density Clustering for High Dimension and Low Sample Size Data
    9 Aug 2026Proceedings of the 32nd ACM SIGKDD Conference on Knowledge Discovery and Data Mining V.1508-519Association for Computing Machinery (ACM)
    Co-authors:
    • Jiang B,
    • Wang Z,
    • Yang J
    DOIDOI: 10.1145/3770854.3780293 (opens in a new tab)⁠
    Clustering on high-dimensional and low sample size (HDLSS) data remains a critical, persistent challenge where extreme sparsity and noise confound cluster analysis. This creates a dilemma: spectral methods fail as distance metrics degrade, while deep clustering tends to over-fit scarce data. To break this dilemma, a Self-Enhanced Density Clustering (SEDC) framework that integrates the cluster structure discovery and embedding representation learning into an iterative enhancement process is proposed in this paper. Specifically, SEDC uses adaptive density-derived centroids to parameterize probabilistic soft labels, which in turn supervise a lightweight multilayer perceptron (MLP) to learn the low-dimensional embedding from data. The resulting embedding provides a refined metric space for further generating superior labels in the subsequent interaction process. This feedback forms a mutual reinforcement that progressively enhances the discrimination of embedding while rigorously mitigating over-fitting. Extensive experiments on 43 challenging HDLSS datasets demonstrate state-of-the-art performance, substantially outperforming popular clustering methods. This work delivers a principled and promising solution for robust data clustering in HDLSS situations.
  • JOURNAL ARTICLE
    Building a Global Research Network for Fair, Accountable, Interpretable, and Responsible AI in Emergency Care: Protocol for a FAIR-EC Study
    4 Aug 2026JMIR Research Protocols15:e74202JMIR Publications
    Co-authors:
    • Hong C,
    • Liew JCK,
    • Yu J
    DOIDOI: 10.2196/74202 (opens in a new tab)⁠
    Background: The current landscape of emergency care (EC) is marked by high demand, leading to issues such as emergency department boarding, overcrowding, and subsequent delays that impact the quality and safety of patient care. Integrating data science into EC can enhance decision-making with predictive, preventative, personalized, and participatory approaches. However, gaps in adherence to fairness, accountability, interpretability, and responsibility are evident, particularly due to barriers to data-sharing, which often result in a lack of transparency and robust oversight in these applications. Objective: The FAIR-EC (Fair, Accountable, Interpretable, and Responsible-Emergency Care) collaboration adapts the existing Fair, Accountable, Interpretable, and Responsible principles to address emerging challenges as data science integrates with EC. This initiative aims to transform EC by establishing ethical artificial intelligence standards specifically tailored for this integration. By bridging the gap between EC professionals, data scientists, and other stakeholders, the collaboration promotes international cooperation that leverages advanced data science techniques to enhance EC outcomes across different care settings. Methods: We propose a federated research design to analyze extensive datasets from various global institutions without compromising patient privacy. This approach transforms epidemiological research with advanced data science techniques, emphasizing the harmonization of data for comprehensive analyses across different health care systems. Results: The FAIR-EC initiative has facilitated the identification and harmonization of datasets from diverse geographical regions, enabling the examination of regional variations in EC practices. As of paper submission, participating sites have identified retrospective EC datasets totaling >2 million records (eg, Duke Health >400,000 and Singapore General Hospital >1.7 million records). Initial projects have demonstrated feasibility and operational readiness, including implementation of federated workflows and ongoing development of a federated scoring system, cross-site evaluation, and adaptation of association studies and predictive models across various regions. Cross-site harmonization and pilot analyses are underway (with local ethics approvals in progress), and first multisite results are expected to be submitted in mid-late 2026, with additional project-level publications anticipated in 2027. These efforts highlight the feasibility of leveraging advanced data science techniques to address the complexities of EC while preserving patient privacy without centralizing individual-level data. This project was funded from September 1, 2022, to August 31, 2023. Conclusions: FAIR-EC integrates data science ethically and effectively into EC, addressing challenges such as fragmented data, real-time handoffs, and public health crises. Its federated design harmonizes diverse data streams while preserving privacy, and its emphasis on ethical artificial intelligence aligns with the dynamic nature of EC. Despite challenges in data variability and system complexity, FAIR-EC establishes a strong foundation for innovation in global EC.
  • JOURNAL ARTICLE
    Multi-Task Learning for OSA Detection and Sleep Staging via Multi-Scale Modeling
    Jul 2026IEEE Journal of Biomedical and Health Informatics30(7):5881-5893Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Wang Z,
    • Yang T,
    • Zhu Y
    DOIDOI: 10.1109/jbhi.2025.3647317 (opens in a new tab)⁠
    Obstructive sleep apnea (OSA) and sleep fragmentation are closely linked physiological phenomena that play crucial roles in the diagnosis and management of sleep disorders. While numerous deep learning models have been developed for either OSA detection or sleep stage classification, few attempts have been made to address both tasks simultaneously. To this end, we propose MT-TASPPNet (Multi-Task Triple Atrous Spatial Pyramid Pooling Network), a unified multi-modal multi-task network that jointly performs automatic OSA event detection and sleep staging. The model integrates modality-specific feature extractors for EEG, ECG, and airflow signals, and employs Atrous Spatial Pyramid Pooling modules in both the modality-specific and shared representation pathways to capture multi-scale temporal-frequency patterns. Additionally, an EOG-guided prior mechanism is incorporated to enhance the discrimination of subtle sleep stages. We use a 3-min input window (1-min target with $\pm$ 1-min context) and evaluate our method on three large-scale datasets: SHHS1, SHHS2, and Sydney Sleep Biobank. The model achieves OSA detection accuracy between 0.798 and 0.884 (MF1: 0.772 to 0.821), and sleep staging accuracy between 0.776 and 0.834 (MF1: 0.735 to 0.749, $\mathcal {K}$: 0.697 to 0.77). Notably, the model maintains consistent performance despite data heterogeneity and individual variability. These results validate the stability and adaptability of MT-TASPPNet in clinical settings, paving the way for efficient and scalable multi-task sleep analysis systems.
  • JOURNAL ARTICLE
    Differential Effects of Sleep Respiratory Event Types on Heart Rate Variability: Central Apnea as the Most Significant
    8 Jun 2026Diagnostics16(12):1770MDPI
    Co-authors:
    • Zhao T,
    • Fu C,
    • Chen W
    DOIDOI: 10.3390/diagnostics16121770 (opens in a new tab)⁠
    <b>Background:</b> Sleep-disordered breathing (SDB) is frequently accompanied by autonomic nervous system (ANS) dysfunction, which is closely associated with an increased incidence of cardiovascular diseases and elevated mortality risk. Heart rate variability (HRV) serves as a classic metric for evaluating sympathovagal balance; however, the specific impacts of four distinct types of respiratory events-obstructive apnea (OA), central apnea (CA), mixed apnea (MA), and hypopnea (HYP)-on HRV remain underinvestigated. Utilizing ultra-short-term HRV analysis, this study aimed to evaluate the immediate effects of different respiratory events on ANS function, while further exploring the modulatory roles of arousal, Apnea-Hypopnea Index (AHI) severity and sleep stages (non-rapid eye movement [NREM] vs. rapid eye movement [REM]). <b>Methods:</b> A total of 108 patients with SDB undergoing overnight polysomnography (PSG) were included. A total of 19,862 respiratory events, including obstructive apnea (OA), central apnea (CA), mixed apnea (MA), and hypopnea (HYP), were analyzed using 15 s ECG segments. Linear mixed-effects models (LMMs) and estimated marginal means (EMMs) with Sidak-adjusted pairwise comparisons were constructed to evaluate differences in ECG-derived features and to analyze differences between event types. <b>Results:</b> Central apnea (CA) was associated with significantly reduced HRV and heart rate indices, including Standard Deviation of Successive Differences (SDSD), Root Mean Square of the Successive (RMSSD), Standard Deviation 1 (SD1), and heart rate (HR), compared with other respiratory event types (all <i>p</i> &lt; 0.05). Across all event types, HRV metrics exhibited consistent dynamic changes before, during, and after respiratory events (all <i>p</i> &lt; 0.001), characterized by a decrease during the event followed by post-event recovery. In the interaction effect of sleep stage, SDSD was significantly lower in CA compared with both OA (estimate = -11.67, 95% CI -18.78 to -4.59, <i>p</i> &lt; 0.001) and HYP (estimate = -11.38, 95% CI -18.55 to -4.20, <i>p</i> &lt; 0.001) during NREM sleep. No significant differences in HRV parameters, heart rate, or QRS duration were observed between OA and HYP (all <i>p</i> &gt; 0.05). <b>Conclusions:</b> This study is the first to elucidate the differential impacts of four distinct types of sleep respiratory events on ultra-short-term HRV, confirming that CA events exert the most profound effects on autonomic function. These findings suggest that the proportion of CA occurrences could serve as a more precise biomarker for identifying individuals at high risk for cardiovascular diseases within the SDB population.
  • JOURNAL ARTICLE
    Computational neuroelectrophysiology and artificial intelligence for drug-resistant epilepsy: recent advances, current challenges, and future directions
    1 Jun 2026Journal of Neural Engineering23(3):031003IOP Publishing
    Co-authors:
    • Wang Y,
    • Yan Z,
    • Gong Y
    DOIDOI: 10.1088/1741-2552/ae6bf4 (opens in a new tab)⁠
    Drug-resistant epilepsy (DRE) affects approximately 30% of epilepsy patients, with surgical cure rates below 70%. This challenge drives a fundamental paradigm shift from localizing a discrete epileptogenic zone toward characterizing and modulating the dysfunctional brain networks that initiate and propagate seizures. This review critically synthesizes how computational neuroelectrophysiology and artificial intelligence (AI) converge to propel this shift. We chart the trajectory from quantifying local biomarkers, including high-frequency oscillations and excitation-inhibition balance metrics, to mapping the topological properties of epileptic networks through functional and effective connectivity. The integration of these network features with AI techniques, particularly spatiotemporal deep learning architectures, has demonstrated significant potential for enhancing both the localization of the epileptogenic network and the prediction of postoperative outcomes. However, the translation of this network-centric paradigm into clinical practice remains constrained by several challenges, including spatial sampling bias, the inherent label instability of surgical outcomes, and the 'black-box' interpretability crisis. Future directions must emphasize EEG foundation models, causal AI, and the development of interactive multimodal AI agents. The convergence of mechanism-driven network models and data-driven AI frameworks promises a new era of personalized, network-guided therapy for DRE.
  • JOURNAL ARTICLE
    MABNSleepNet: A multi-view self-attention architecture based on brain network for neonatal sleep staging
    Jun 2026Biomedical Signal Processing and Control118:109651Elsevier
    Co-authors:
    • Zhou L,
    • Xu Y,
    • Wang Y
    DOIDOI: 10.1016/j.bspc.2026.109651 (opens in a new tab)⁠
    Existing deep learning-based automatic sleep staging methods for neonates predominantly rely on CNN or RNN architectures, often overlooking information on inter-channel spatial and inter-stage temporal dynamics. Although GNN-based and graph-based methods can leverage such information, they solely focus on functional connectivity from linear relationships instead of incorporating effective connectivity from information flow. Thus, a multi-view self-attention based on the brain network method is proposed for neonatal sleep staging (MABNSleepNet), which consists of a Brain Network Extractor (BNE), a Context-attaching Module (CAM), a Multi-view Self-attention Module (MSAM), and a Feature-aggregating Module (FAM). The proposed method leverages multi-view self-attention and brain connectivity analysis to comprehensively capture both spatial, temporal, and frequency-domain features, while incorporating inter-stage temporal context for accurate neonatal sleep staging. It was validated on a clinical neonatal sleep dataset from the Children’s Hospital of Fudan University (CHFU) with 64 eight-channel EEG recordings. Employing the subject-wise 10-fold validation method with six testing set and 58 training set, the proposed method achieved impressive results on two-stage (wakefulness and sleep) and three-stage (wakefulness, active sleep, and quiet sleep) tasks respectively: with accuracies of 0.920 and 0.862, F1-scores of 0.909 and 0.861, as well as Cohen’s Kappa coefficients of 0.817 and 0.793. Experiment results demonstrate the proposed method’s superiority over most current state-of-the-art methods in neonatal sleep staging, providing a novel avenue for in-depth analysis of sleep staging from the brain connectivity perspective.
  • JOURNAL ARTICLE
    Leveraging Synchrosqueezing Transform (SST)-based representations in a dual-stream attention framework to enhance sleep apnea detection and subtyping
    29 May 2026Frontiers in Neuroscience20:1853573Frontiers
    Co-authors:
    • Zhao T,
    • Fu C,
    • Li Y
    DOIDOI: 10.3389/fnins.2026.1853573 (opens in a new tab)⁠
    Introduction: Sleep apnea and hypopnea syndrome (SAHS) is a prevalent disorder with profound adverse effects on health and overall quality of life, thereby necessitating the development of accurate and accessible screening tools. Electrocardiogram (ECG)-based analysis, being non-invasive and readily deployable in low-cost hardware, offers a particularly convenient approach for SAHS screening and preliminary diagnosis. However, conventional time-frequency analysis often fails to capture the subtle yet critical patterns in ECG signals due to the Heisenberg uncertainty principle, leading to limited resolution and information loss. Methods: To overcome these limitations, this study proposes a Dual Stream Cross Attention Fusion Network (DSCAFNet) based on the uncertainty-mitigated time-frequency representations generated via Synchrosqueezing Transform (SST). The framework uniquely constructs two complementary, high-fidelity SST-based representations, which are strategically designed to provide distinct yet synergistic perspectives on the complex, non-stationary dynamics of SAHS. A dedicated cross-attention fusion module then harnesses these complementary views, enabling the model to discriminatively integrate multi-resolution features for significantly enhanced pattern recognition. Results: Extensively evaluated on the public Apnea-ECG dataset, DSCAFNet achieves an accuracy of 0.9572, a sensitivity of 0.9575, a specificity of 0.9584, and an F1-score of 0.9557, performing on par with state-of-the-art methods. More importantly, rigorous validation on a private Huashan-apnea dataset yields an accuracy of 0.9003 for binary classification and 0.7564 for four-class subtyping, demonstrating strong effectiveness and generalization. Conclusion: These consistent results across datasets highlight DSCAFNet as a promising framework for intelligent and accessible SAHS screening, with potential for integration into portable data acquisition systems combined with cloud-based analysis.
  • PREPRINT
    A Lightweight Temporal-Spatial Fusion Network for Neonatal Sleep Staging
    24 Apr 2026Preprints.org202604.1735.v1MDPI
  • JOURNAL ARTICLE
    Task-specific machine learning system for automatic assessment of multi-limb bradykinesia in Parkinson's disease
    10 Apr 2026Frontiers in Neuroscience20:1774097Frontiers
    Co-authors:
    • Zhang Y,
    • Chen Q,
    • Wu H
    DOIDOI: 10.3389/fnins.2026.1774097 (opens in a new tab)⁠
    Introduction: Bradykinesia, a cardinal physical dysfunction of Parkinson's disease (PD), is generally evaluated by Section III of the Movement Disorders Society-sponsored revision of the unified Parkinson's disease rating scale (MDS-UPDRS). The evaluation process requires the supervision of clinicians; therefore, the results may be subjective and increase clinicians' workload. Methods: To compensate for these drawbacks, this study proposes a task-specific machine learning system that incorporates wearable sensors to automatically monitor bradykinesia. Initially, this study enhanced the peak detection algorithm by considering specific motion characteristics, such as movement amplitude, to make it more adaptable to individualized signals. Furthermore, a task-specific score prediction system was proposed, incorporating the optimal sensor placement positions and appropriate score prediction algorithms. Specifically, seven machine learning models and four ensemble methods were explored for each of the five MDS-UPDRS III tasks. Results: The system was tested in 21 patients and eight control individuals. The performance of the system was evaluated under three scenarios: precise prediction (0 vs. 1 vs. 2 vs. 3), abnormal/normal [0 vs. (1, 2, 3)], and normal-moderate/severe [(0,1,2) vs. 3], with the highest average F1 score reaching 0.8722 and the lowest total root mean square error at 0.3214 among tasks in critical status prediction. Furthermore, this study, through statistical analysis, suggested specific scoring features tailored to each task. Discussion: This study demonstrated the feasibility of accurately and automatically monitoring bradykinesia of PD.
  • JOURNAL ARTICLE
    A BiLSTM-Based Framework for Sleep Spindle and K-complex Detection with Enhanced Segment-Level Learning
    1 Apr 2026IEEE Transactions on Biomedical EngineeringPP(99):1-10Institute of Electrical and Electronics Engineers (IEEE)
    Sleep spindles and K-complexes in electroencephalo gram (EEG) signals are brief yet physiologically essential signatures of the sleeping brain, supporting memory consolidation, arousal regulation, and neurological assessment. However, existing detection methods often face severe class imbalance, temporal inconsistencies, and uncertain event boundaries. We proposed a unified, physiologically informed framework that integrates data preprocessing, multimodal feature extraction, temporal modeling, and event-level refinement. Context-aware negative filtering and segment-level oversampling effectively alleviated severe class imbalance; multimodal feature combination captured both spectral and morphological cues; a Bidirectional Long Short-Term Memory (BiLSTM) backbone enhanced by segment level dropout and bidirectional hard example mining improves robustness under imbalance; and a physiologically plausible post-processing enforced temporal coherence on the predicted sequences. Evaluations on the publicly available polysomnog raphy datasets DREAMS and MASS demonstrated consistent 3-10% F1-score improvements over state-of-the-art baselines. The proposed framework attained event-level F1-scores of 0.796 (sleep spindles on DREAMS), 0.938 (K-complexes on DREAMS), 0.882 (sleep spindles on MASS), and 0.903 (K-complexes on MASS), substantially outperforming recent deep-learning-based detectors.
  • JOURNAL ARTICLE
    Multidomain Selective Feature Fusion and Stacking Based Ensemble Framework for EEG-Based Neonatal Sleep Stratification
    Apr 2026IEEE Journal of Biomedical and Health Informatics30(4):2828-2838Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Irfan M,
    • Wang L,
    • Shahid H
    DOIDOI: 10.1109/jbhi.2025.3530107 (opens in a new tab)⁠
    Employing a minimal array of electroencephalography (EEG) channels for neonatal sleep stage classification is essential for data acquisition in the Internet of Medical Things (IoMT), as single-channel and edge-based features can reduce data transfer and processing requirements, enhancing cost-effectiveness and practicality. In this paper, we evaluate the efficacy of a single channel and the viability of a binary classification scheme for discerning awake and sleep states and transitions to quiet sleep. For this, two datasets of EEG signals for neonate sleep analysis were recorded from Children's Hospital of Fudan University, Shanghai, comprising recordings from 64 and 19 neonates, respectively. From each epoch, a diverse ensemble of 490 features was extracted through a blend of discrete and continuous wavelet transforms (DWT, CWT), spectral statistics, and temporal features. In addition, we introduced an innovative hybrid univariate and ensemble feature selection approach with multidomain feature fusion, a stacking-based ensemble classifier that outperforms existing work. We achieved 90.37%, 91.13%, and 94.88% accuracy for sleep/awake, quiet sleep/non-quiet sleep, and quiet sleep/awake, respectively. This was corroborated by significant Kappa values of 77.5%, 80.29%, and 89.76%. Using SelectPercentile, we devised three distinct feature selection mechanisms: one using DWT, one with CWT, and another incorporating both spectral and temporal features. Subsequently, SelectKBest was used to determine the most effective features. For our stacked model, we incorporated a trifecta of the ExtraTree model with variable estimators, a Random Forest, and an Artificial Neural Network (ANN) as base classifiers, and for the final prediction phase, ANN was implemented again. The model's performance was evaluated using K-fold and leave-one-subject cross-validation.
  • PREPRINT
    Automated high-throughput fabrication of patient-specific vessel-on-chips enables a generative AI digital twin—Cascade Learner of Thrombosis (CLoT) for personalized thrombosis prediction
    5 Mar 2026bioRxiv2026.03.03.709446Cold Spring Harbor Laboratory
  • PREPRINT
    ECG2Sleep: Efficient Sleep Staging with a Hybrid Dual-Stream Network on Single-Lead ECG
    2026SSRN Electronic JournalElsevier
    Co-authors:
    • Wang K,
    • Tang Z,
    • Wang J
    DOIDOI: 10.2139/ssrn.7499092 (opens in a new tab)⁠
  • JOURNAL ARTICLE
    Entropy-Based Graph Learning Framework for Cross-Subject Detection of Electrical Status Epilepticus During Sleep (ESES)
    2026IEEE Transactions on Neural Systems and Rehabilitation Engineering34:3255-3265Institute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Lin W,
    • Luo T,
    • Zhou L
    DOIDOI: 10.1109/tnsre.2026.3710242 (opens in a new tab)⁠
    Electrical Status Epilepticus during Sleep (ESES) is a severe childhood epilepsy syndrome marked by sleep-induced and near-continuous epileptiform discharges, often leading to cognitive and behavioral impairments. Early and reliable detection is clinically critical but remains challenging due to the complex nonlinear EEG dynamics, strong inter-channel dependencies, and the limitations of conventional feature representations and fixed connectivity assumptions. To address these challenges, we propose GCN-AGLCA, a data-driven graph learning framework for cross-subject ESES detection, which jointly models multiband entropy-based complexity features, adaptively learns subject-specific functional connectivity graphs without predefined assumptions, and incorporates a channel attention mechanism to prioritize clinically relevant EEG channels during graph convolution. Experimental results show that combined entropy features outperform individual entropy measures and conventional time-frequency representations, achieving a classification accuracy of 84.00% and yielding more stable training and improved generalization. Furthermore, evaluated via leave-one-subject-out cross-validation on EEG recordings from 58 pediatric patients, the proposed framework attains a superior average accuracy of 77.82%, along with a lower average error rate of 6.39%, and enhanced training stability compared to the reproduced state-of-the-art baseline model. These results demonstrate that entropy-informed adaptive graph learning offers a robust and clinically interpretable approach for automated ESES identification.
  • JOURNAL ARTICLE
    Guest Editorial: Special Issue on User-Centered Innovations in Upper-Limb Prosthetics
    1 Jan 2026IEEE Transactions on Neural Systems and Rehabilitation Engineering34:i-iiInstitute of Electrical and Electronics Engineers (IEEE)
    Co-authors:
    • Scheme E,
    • Gherardini M,
    • Chen W
    DOIDOI: 10.1109/tnsre.2026.3702278 (opens in a new tab)⁠